Operational |
Early 2003 |
Source characteristics |
Superbend |
Energy range |
3-60 keV |
Monochromator |
Double crystal: Si(111) and multilayer |
Calculated flux (1.9 GeV, 400 mA) |
700 at 10 keV, 150 at 30 keV, and 50 at 40 keV
in units of photons/s/µm2/actual bandwidth over a 0.6
x 6 cm area |
Resolving power (E/DE) |
Si(111): 7,000; multilayer: 330 |
Endstations |
Conventional radiography (10-45 keV)) |
Characteristics |
Radiography spatial resolution ~1 µm |
Detectors |
Scintillator plus CCD |
Spot size at sample (FWHM) |
1-6 mm high, 60 mm wide |
Samples |
Format |
Universal except for the need to fit within the illuminated field |
Sample environment |
Atmosphere |
Experimental techniques |
Tomography |
Local contact/Spokesperson |
Name: Malcolm Howells
Affiliation: Advanced Light Source, Berkeley Lab
Phone: (510) 486-4949
Fax: (510) 486-7696
Email: mrhowells@lbl.gov |